SENTINEL DUAL 10000VA ONLINE UPS NO BATTERY


Minste bestillingsenhet: 1
Riello SDU 10000TMER
Power 10000VA/10000W
Back-up (70% load) 0 min - ER
TM - 3:1 phase
ER - Extra charging current
Up to 3 Sentinel Duals can be operated in parallel in either capacity or N+1 redundant configuration offering increased reliability for critical system. The Sentinel Dual can be installed as Tower (floor standing) or Rack, ideal for network and server rack applications.

Simplified installation
• Can be installed on the floor (tower version) or in rack mount cabinets (rack version). The display panel can be rotated.
• Low noise (<48 dBA): can be installed in any environment thanks to its high frequency switching inverter and PWM load-dependent digitally controlled fan
• External bypass option for maintenance with interruption-free switching
• Operation guaranteed up to 40°C (the components are designed for high temperatures and are thus subject to less stress at normal temperatures)
• Built-in IEC output sockets with thermal protection.

Operating mode selection
Functions can be programmed via software or manually via the front display panel.
• On line: efficiency up to 95%
• Eco Mode: to increase efficiency (up to to 98%), allows for the selection of Line Interactive technology (VI) to power low priority loads from the mains supply
• Smart Active: the UPS automatically decides upon the operating mode (VI or VFI) based on the quality of the mains power supply
• Emergency: the UPS can be selected to function only when the mains power supply fails (emergency only mode).
• Frequency converter operation (50 or 60 Hz).

High battery reliability
• Automatic and manual battery test
• Reduced ripple component (detrimental to the batteries) using a low ripple current discharge (LCRD) system
• Batteries are user replaceable without switching off equipment and without interruption to the load (Hot Swap)
• Unlimited extendible runtime using matching Battery Boxes
• The batteries do not cut in during mains failures of <20 ms (high hold up time) or when the input supply is between 184 V to 276 V.

Battery optimisation
The wide input voltage range and a high hold-up time minimise battery usage and increase efficiency and battery life; for smaller power breaks, energy is drawn from a group of appropriately-sized capacitors.

EnergyShare
10 A configurable IEC output sockets allow for runtime optimisation by programming the switching off of low priority loads on mains failure; alternatively, emergency loads that are normally not powered when mains is
present can be activated.

Advanced communications
• Advanced multi-platform communications for all operating systems and network environments: PowerShield 3 monitoring and shutdown software for Windows operating systems 10, 8, 7, Hyper-V, 2019, 2016, 2012, and previous versions, Mac OS X, Linux, VMWare ESXi, Citrix XenServer and other Unix operating systems
• Plug and play function
• USB port
• RS232 serial port
• Slot for installation of communications boards.

Unity Power Factor
• More power delivered
• More real output power (W)
Up to 3 Sentinel Duals can be operated in parallel in either capacity or N+1 redundant configuration offering increased reliability for critical system. The Sentinel Dual can be installed as Tower (floor standing) or Rack, ideal for network and server rack applications.

Simplified installation
• Can be installed on the floor (tower version) or in rack mount cabinets (rack version). The display panel can be rotated.
• Low noise (<48 dBA): can be installed in any environment thanks to its high frequency switching inverter and PWM load-dependent digitally controlled fan
• External bypass option for maintenance with interruption-free switching
• Operation guaranteed up to 40°C (the components are designed for high temperatures and are thus subject to less stress at normal temperatures)
• Built-in IEC output sockets with thermal protection.

Operating mode selection
Functions can be programmed via software or manually via the front display panel.
• On line: efficiency up to 95%
• Eco Mode: to increase efficiency (up to to 98%), allows for the selection of Line Interactive technology (VI) to power low priority loads from the mains supply
• Smart Active: the UPS automatically decides upon the operating mode (VI or VFI) based on the quality of the mains power supply
• Emergency: the UPS can be selected to function only when the mains power supply fails (emergency only mode).
• Frequency converter operation (50 or 60 Hz).

High battery reliability
• Automatic and manual battery test
• Reduced ripple component (detrimental to the batteries) using a low ripple current discharge (LCRD) system
• Batteries are user replaceable without switching off equipment and without interruption to the load (Hot Swap)
• Unlimited extendible runtime using matching Battery Boxes
• The batteries do not cut in during mains failures of <20 ms (high hold up time) or when the input supply is between 184 V to 276 V.

Battery optimisation
The wide input voltage range and a high hold-up time minimise battery usage and increase efficiency and battery life; for smaller power breaks, energy is drawn from a group of appropriately-sized capacitors.

EnergyShare
10 A configurable IEC output sockets allow for runtime optimisation by programming the switching off of low priority loads on mains failure; alternatively, emergency loads that are normally not powered when mains is
present can be activated.

Other features
• Selectable output voltage (220-230-240 V)
• Dual input supplies configuration (SDU 10000 DI and SDU 10000 DI ER)
• Auto-restart when mains power is restored (programmable via software)
• Bypass on: when the machine is switched off, it automatically goes into bypass and battery charge mode
• Minimum load switch-off
• Low battery warning
• Start-up delay
• Total microprocessor and DSP control
• Automatic bypass without interruption
• Use of custom power modules
• Status, measurements and alarms available on standard backlit display
• UPS digital updating (flash upgradeable)
• Output sockets protected with resettable thermal switch
• Back-feed protection standard: to prevent energy from being fed back to the network
• Manual switching to bypass.
Frakt Vekt 29.0 kg
Vekt 23.0 kg
Lengde 640,000000 mm
Bredde 131,000000 mm
Høyde 448.0 mm
Areal 83840.0 mm2
Volum 3.756032E7 mm3

BATTERY EXT FOR RIELLO SDU8000-10000 7Ah

Battery Extension Packs (BEPs) for the SDU 5000/6000 from Riello UPS. The battery extension pack plugs into the UPS rear panel battery extension connector to provide extended runtime (battery backup) support for the load(s) connected to the UPS.

Minste bestillingsenhet: 1
Nyhet

Bulgin C14 Cable Mount IEC Connector Male, 10A, 250 V ac

Terminerbar C14-plugg for UPS
Spenning: 250V AC
Strøm: 10A
Type: Han

Minste bestillingsenhet: 1

Rack guide kit 600-1000mm

Riello Kit Universal Rack Guides ZDVD001A

Minste bestillingsenhet: 1

RELEKORT 230V + ESD PORT

Contacts / EPO board.
Allows remote commands.
Fits most Riello UPS.

Minste bestillingsenhet: 1

SNMP Network/ Modbus card

SNMP Card UTP Ethernet.
Communication by LAN.
TCP/IP, HTTP, SNMP.

Minste bestillingsenhet: 1

UPS-Forgrening

Forgrening fra IEC kontakt til schuko (3 veis).

Minste bestillingsenhet: 1